# TA6000.

![TA6000](https://au.elvorka.com/assets/optimized/3767e02b99d59eea-1254-q92.webp)

Integrated system

# TA6000.

Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration.

INVERTER  Included

ENCLOSURE  Not specified

NOMINAL ENERGY  10.24–20.48 kWh

AC CONFIGURATION  120 V US / 230 V EU AC options

[Start your project ↗](https://au.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | AC options (kW) |
| --- | --- | --- |
| TA6000-M2 | 10.24 | 6–10 |
| TA6000-M3 | 15.36 | 6–12 |
| TA6000-M4 | 20.48 | 6–12 |

Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TA6000-M2 | 590 × 570 × 1880 / W × D × H | 244 |
| TA6000-M3 | 590 × 570 × 1880 / W × D × H | 286 |
| TA6000-M4 | 590 × 570 × 1880 / W × D × H | 328 |

Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional
Temperature: Operating −20 to 60 °C

## Different climates. A specific place for your battery.

Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position.

Temperature:  Operating −20 to 60 °C

ENCLOSURE  Not specified

01

### Summer heat · garage or dedicated utility room

Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable.

Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration.

Does the room trap afternoon or roof heat?

- What temperature and output derating apply to this exact configuration?

- Can cooling and service space remain clear after installation?

02

### Tropical north · humidity and actual exposure

The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment.

Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air.

Is the room dry through the wet season?

- Can water, condensation or coastal salt reach the equipment?

- Does the exact model's placement guidance cover the proposed environment?

03

### Cooler winter location · southern or elevated home

Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home.

If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation.

Can the battery position fall below 0 °C while charging?

- Is heating included and confirmed for this exact model?

- Does the equipment room stay dry during cold-to-warm changes?

Specifications

- Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings.

- Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature.

- Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility.

[![Original terminal labels](https://au.elvorka.com/assets/product-details/ta-terminal-map.png)](https://au.elvorka.com/assets/product-details/ta-terminal-map.png)

Original terminal labels  Connection panel labelled for load, grid, optional generator, PV and communication.

[![Terminal panel close-up](https://au.elvorka.com/assets/product-details/ta-terminal-closeup.png)](https://au.elvorka.com/assets/product-details/ta-terminal-closeup.png)

Terminal panel close-up  Close-up of the cabinet terminal panel.

[![Original breaker labels](https://au.elvorka.com/assets/product-details/ta-breaker-map.png)](https://au.elvorka.com/assets/product-details/ta-breaker-map.png)

Original breaker labels  Battery, PV1, PV2, load and grid breakers in the illustrated compartment.

[![Breaker compartment close-up](https://au.elvorka.com/assets/product-details/ta-breaker-closeup.png)](https://au.elvorka.com/assets/product-details/ta-breaker-closeup.png)

Breaker compartment close-up  Circuit breakers within the cabinet's breaker compartment.

[![Upper cabinet and service bay](https://au.elvorka.com/assets/product-details/ta-service-bay.png)](https://au.elvorka.com/assets/product-details/ta-service-bay.png)

Upper cabinet and service bay  Upper cabinet compartment with the inverter and connection area.

[![Cell assembly detail](https://au.elvorka.com/assets/product-details/ta-cell-assembly.png)](https://au.elvorka.com/assets/product-details/ta-cell-assembly.png)

Cell assembly detail  Battery cell tops in a partial internal illustration.

### Know your interfaces.

#### Power connections

Load Output  Output position identified as Load Output in the brochure.

Grid Input  Connection position identified as Grid Input.

Generator Input (optional)  The generator input is explicitly marked optional in the original callout.

PV Input  PV connection area identified by the original callout.

PV1 Input Breaker  Breaker identified for PV1 Input.

PV2 Input Breaker  Breaker identified for PV2 Input.

#### Communication

Communication Port  Connection area labelled Communication Port. No protocol pin assignments are specified in this component view.

#### Controls & indicators

Battery Breaker  Breaker labelled for the battery section.

Load Breaker  Breaker identified for the load connection.

Grid Breaker  Breaker identified for the grid connection.

Source: Residential ESS brochure · PDF page 8 · printed pages 15-16

---

https://au.elvorka.com/en/products/ta6000/