# ELVORKA · Australia > Residential battery-only and integrated energy storage. Public contact: eric@elvorka.com. The United States English edition is the main website. Country editions describe installation context; they do not establish local stock, offices, certification or grid approval. Product facts follow supplied literature. Scenes are illustrations, not customer-installation evidence. ## English · en-AU - [Home storage. Planned around you .](https://au.elvorka.com/en/index.md): https://au.elvorka.com/en/ - [TR Pro.](https://au.elvorka.com/en/products/tr-pro/index.md): https://au.elvorka.com/en/products/tr-pro/ - [EU 230 V.](https://au.elvorka.com/en/products/eu-230v/index.md): https://au.elvorka.com/en/products/eu-230v/ - [HP Ultra.](https://au.elvorka.com/en/products/hp-ultra/index.md): https://au.elvorka.com/en/products/hp-ultra/ - [TA6000.](https://au.elvorka.com/en/products/ta6000/index.md): https://au.elvorka.com/en/products/ta6000/ - [TR standard.](https://au.elvorka.com/en/products/tr-standard/index.md): https://au.elvorka.com/en/products/tr-standard/ - [HP K.](https://au.elvorka.com/en/products/hp-k/index.md): https://au.elvorka.com/en/products/hp-k/ - [TB rack.](https://au.elvorka.com/en/products/tb-rack/index.md): https://au.elvorka.com/en/products/tb-rack/ - [A clearer view of home storage.](https://au.elvorka.com/en/blog/index.md): https://au.elvorka.com/en/blog/ - [Inside the ELVORKA collection.](https://au.elvorka.com/en/news/index.md): https://au.elvorka.com/en/news/ - [How much battery storage does your home need?](https://au.elvorka.com/en/blog/battery-capacity/index.md): https://au.elvorka.com/en/blog/battery-capacity/ - [Choose the battery location before installation.](https://au.elvorka.com/en/blog/installation-environment/index.md): https://au.elvorka.com/en/blog/installation-environment/ - [The international ELVORKA product collection is available online.](https://au.elvorka.com/en/news/product-collection/index.md): https://au.elvorka.com/en/news/product-collection/ - [Original product views and interface notes are now easier to explore.](https://au.elvorka.com/en/news/technical-library/index.md): https://au.elvorka.com/en/news/technical-library/ - [Home storage. Clearly specified.](https://au.elvorka.com/en/about/index.md): https://au.elvorka.com/en/about/ - [Clear sources. Visible limits.](https://au.elvorka.com/en/sources/index.md): https://au.elvorka.com/en/sources/ - [Let’s plan your storage project.](https://au.elvorka.com/en/contact/index.md): https://au.elvorka.com/en/contact/ ## Structured reference - [Product catalogue](https://au.elvorka.com/data/product-catalogue.json): exact model data; source qualifications and assumptions kept separate. - [Sitemap](https://au.elvorka.com/sitemap.xml): canonical public HTML pages. --- # Home storage. Planned around you . HOME ENERGY STORAGE / AUSTRALIA # Home storage. Planned around you . Add a matched LFP battery to a compatible existing system, or plan a new all-in-one installation. Start with your inverter, equipment-room conditions and the loads you want to support. [Explore the collection](https://au.elvorka.com/en/#products)[Find your fit](https://au.elvorka.com/en/#planner) One home. A considered system. Integrated storage or a battery for your inverter. ![EU 230 V — INSTALLATION ILLUSTRATION](https://au.elvorka.com/assets/optimized/f1bf71b24d73c546-1536-q92.webp) INSTALLATION ILLUSTRATION 01 / 03 INSTALLATION ILLUSTRATION [INVERTER INCLUDED EU 230 V Integrated battery + inverter](https://au.elvorka.com/en/#products) SMALLER FOOTPRINT. GREATER POSSIBILITIES. 07 Product families 29 Listed configurations 5.12–48 kWh Nominal energy across the collection [Product tour](https://au.elvorka.com/en/#product-tour) Product tour ## One home. A considered system. Integrated storage or a battery for your inverter. RESIDENTIAL ENERGY STORAGE / AUSTRALIA LFP ![Installation illustration of a TR Pro battery in a residential equipment area.](https://au.elvorka.com/assets/optimized/f5e5c77bf1c7c797-1536-q92.webp) HOME BATTERY INSTALLATION Product scene illustration [TR PRO / WALL STORAGE ![elvorka TR Pro wall-mounted LFP battery](https://au.elvorka.com/assets/optimized/46a9d9acb1b4d427-1560-q92.webp) Storage. In its element. 10.24 / 16.076 kWh nominal energy 51.2 V NOMINAL DC IP66 ENCLOSURE](https://au.elvorka.com/en/#products) [All products](https://au.elvorka.com/en/#products) 01 TWO WAYS TO STORE ## Start with your setup. A new installation or an existing inverter. Choose your starting point. [INTEGRATED SYSTEMS ### A fresh start. All in one. Battery and inverter in one system. A coordinated starting point for a new installation. EXPLORE ALL-IN-ONE 6 listed configurations](https://au.elvorka.com/en/#products) [BATTERY SYSTEMS ### Your inverter. More possibility. Wall, stack or rack-mounted LFP storage. Match the voltage and confirm compatibility. EXPLORE BATTERIES 23 listed configurations](https://au.elvorka.com/en/#products) TR PRO / MATERIAL & FORM 01 — ENCLOSURE / FRONT ELEVATION PRODUCT DETAIL 03 LOOK A LITTLE CLOSER ## Details you can build around. Start with the chemistry. Check the voltage. Specify the enclosure. Every good installation begins with a clear understanding of the product. LiFePO₄ LFP battery chemistry 51.2 V TR Pro nominal DC voltage IP66 TR Pro enclosure rating CAN / RS485 Communication interfaces [See TR Pro specifications](https://au.elvorka.com/en/#products) ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. 01 ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? 02 ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? 03 ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? Specifications - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. 02 THE COLLECTION ## Storage. Clearly specified. Seven families. Three installation formats. Compare the details that matter. 3 product families ### TR Pro. Wall-mounted. Thoughtfully contained. 10.24 / 16.076 kWh LFP battery storage in a wall-mounted format, with three specified models and an IP66 enclosure. Pair with a compatible external inverter. [Explore all product details ↗](https://au.elvorka.com/en/products/tr-pro/) ### EU 230 V. An integrated starting point. 10.24 / 16.076 kWh An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW. [Explore all product details ↗](https://au.elvorka.com/en/products/eu-230v/) ### HP Ultra. Storage with room to grow. 8–48 kWh A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter. [Explore all product details ↗](https://au.elvorka.com/en/products/hp-ultra/) Confirm configuration, project suitability, inverter compatibility and supply arrangements before ordering. Local approval, VPP participation and incentive eligibility require separate confirmation. Your setup matters. Battery-only products require a compatible external inverter. [Download the full collection](https://au.elvorka.com/downloads/ELVORKA_au_en_Product_Guide.pdf) PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. Look beyond the headline specifications. Explore original product views, labelled interfaces and details for each family. 05 KNOW YOUR ESSENTIALS ## Explore your backup. Start with the essentials you want to keep running. Adjust the load and battery size to explore an indicative backup duration. Battery energy is measured in kWh . Appliance power is measured in kW . Your inverter must support the load. Inverter included in all-in-one systems; external for battery-only products. BACKUP EXPLORER YOUR ESTIMATE Watt / kW Battery capacity 10.24 kWh Average essential load 1.0 kW 0.2 kW 5.0 kW Illustrative planning allowances, not measured household averages or guaranteed runtime. Replace with actual simultaneous loads and check compressor starting demand, battery DC capability, inverter AC output and backup-capable circuits. INDICATIVE BACKUP 8.3 hours How this estimate works Nominal battery capacity × 90% assumed usable depth × 90% assumed inverter efficiency ÷ average load. These are planning assumptions, not guaranteed product ratings. Actual backup varies with usable energy, temperature, battery age, standby use and load changes. Starting currents and inverter limits must be checked separately. [Use this in my project](https://au.elvorka.com/en/#enquiry) OUR PRODUCTS / AT HOME ### A clearer path to your home battery. For Australian homeowners and installation professionals comparing storage: resolve the system match, indoor placement and selected backup circuits together. The scenes illustrate applications; they are not completed local customer projects. EU 230 V / INVERTER INCLUDED #### Add storage to an existing system. Compare the battery voltage range, current limits and supported communications against the exact inverter model and firmware. An existing solar installation does not by itself establish battery compatibility. HP ULTRA / BATTERY ONLY #### Plan a new all-in-one installation. EU and TA6000 combine storage with an integrated inverter. Confirm the selected AC configuration, phase requirements, placement and project documentation without adding a second inverter to the all-in-one design. TR PRO / BATTERY ONLY #### Separate essentials from large loads. Define the refrigeration, lighting, connectivity and selected cooling loads you need. Use the Watt explorer as a planning estimate, then check starting demand and the required backup circuits. Installation illustrations featuring products from this collection. Scenes are composites, not photographs of completed customer projects. Visible layouts are illustrative; final connections, protection and clearances follow the selected model’s installation manual and site design. 06 KNOW YOUR SYSTEM ## Choose with clarity. [elvorka product collection English · PDF · 8 pages PDF](https://au.elvorka.com/downloads/ELVORKA_au_en_Product_Guide.pdf) [elvorka views & interfaces 35 source views · 7 families · English PDF PDF](https://au.elvorka.com/downloads/product-views-and-interfaces.pdf)[Explore the detail library Original product views, labelled interfaces and source references.](https://au.elvorka.com/en/#technical-library) [Original product collection · English PDF ↘](https://au.elvorka.com/downloads/energy-product-collection.pdf) Good questions. Straight answers. Start with the system you have. Choose the storage you need. What should I confirm before adding a home battery in Australia? Confirm the exact battery and inverter pairing, phase arrangement, placement conditions, project documentation and backup design. If you intend to join a VPP, check the exact equipment, firmware and provider requirements separately; this catalogue does not establish compatibility, scheme eligibility or approval. Can I connect a 51.2 V battery to my existing inverter? A nominal voltage match alone does not confirm compatibility. Your installer should verify the inverter’s DC voltage window, charge and discharge current, CAN or RS485 protocol, firmware and protection settings. High-voltage batteries must not be connected to a low-voltage inverter. What should be checked for a project in Australia? Confirm the installation’s AC supply, inverter phase requirements, essential-load circuits and local electrical requirements. The EU integrated range lists 230 V AC and 50 / 60 Hz. TA6000 lists 120 V US and 230 V EU options; specify the required market configuration. The project’s backup circuits and protection requirements need installer review. Can these batteries be installed outdoors? TR Pro and HP Ultra list IP66 enclosures. Other families have different or optional protection ratings. An IP rating alone is not an installation instruction: check the selected model’s temperature limits, clearances, shelter, ventilation and installer requirements. Does more battery capacity mean more output power? No. Capacity in kWh describes stored energy. Power in kW describes the rate energy can be delivered. Battery-side DC ratings and inverter AC output are different. Both the selected battery configuration and inverter must support your operating and starting loads. How do I confirm price, warranty and availability? Prepare a project brief with your city, required loads, existing inverter and selected product. Ask your supplier to confirm the exact configuration, quotation currency, warranty terms, installation scope, delivery timing and after-sales arrangements in writing. Can I add one of these batteries to my existing inverter? Only after checking the exact inverter model and firmware against the battery voltage window, current limits and communication protocol. A battery-only product needs a compatible external inverter; an existing system or a matching nominal voltage alone does not establish compatibility. Will this battery work with my VPP or qualify for an incentive? Confirm the selected equipment and firmware with the specific provider or programme before ordering. VPP control, operating requirements and participation terms are separate checks. This catalogue does not promise VPP compatibility, eligibility, savings or local approval. Can one placement suit both summer heat and winter cold? Assess the full expected temperature range, humidity and exposure at the battery position. Several families list charging from 0 °C, and heating is optional only where specified. Confirm the selected model's limits, protection, ventilation and any derating rather than relying on a national climate average. Your next chapter ## Start with your setup. [01 ### Explore the collection Seven families. Three installation formats.](https://au.elvorka.com/en/#products)[02 ### Find your fit Start with the essentials you want to keep running.](https://au.elvorka.com/en/#planner)[03 ### Prepare my enquiry Tell the story of your home.](https://au.elvorka.com/en/#enquiry) YOUR NEXT CHAPTER ## Let’s plan your system . Tell the story of your home. Prepare a clear project brief to share with your installer or storage supplier. YOUR HOME. YOUR ENERGY. [eric@elvorka.com](mailto:eric@elvorka.com) Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. Your name (optional) Project city * Your email Phone / WhatsApp (optional, include country code) Company (optional) I am planning for Existing inverter Product interest What matters to you? State / region and seasonal conditions Lowest / highest observed temperature; damp or water exposure AC supply and required phase arrangement Your submitted details are saved for the ELVORKA team to review and follow up. Please avoid including passwords, identity documents or unrelated sensitive information. I agree that ELVORKA may use these details to respond to this project enquiry. ELVORKA ## A clearer view of home storage. Practical reading for choosing battery capacity, checking equipment-room conditions and preparing a useful installation brief. --- https://au.elvorka.com/en/ ELVORKA · eric@elvorka.com --- # TR Pro. ![TR Pro](https://au.elvorka.com/assets/optimized/46a9d9acb1b4d427-1560-q92.webp) Low-voltage battery # TR Pro. LFP battery storage in a wall-mounted format, with three specified models and an IP66 enclosure. Pair with a compatible external inverter. INVERTER Compatible external inverter required ENCLOSURE IP66 NOMINAL ENERGY 10.24 / 16.076 kWh BATTERY VOLTAGE 51.2 V nominal DC [Start your project ↗](https://au.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Rated DC (kW) | | --- | --- | --- | | TR6000WX-Pro | 10.24 | 10 | | TR8500WX-Pro | 16.076 | 10 | | TR8500WX-ProU | 16.076 | 10 | Self-heating is optional. Power ratings are battery-side DC; actual AC output depends on the selected inverter. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | TR6000WX-Pro | 802 × 620 × 179 / H × L × D | 95 | | TR8500WX-Pro | 822 × 500 × 250 / H × L × D | 115.5 | | TR8500WX-ProU | 872 × 500 × 250 / H × L × D | 120 | Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ENCLOSURE IP66 01 ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? 02 ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? 03 ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? Specifications - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. The panel illustrates one wheeled representative housing rather than proving every Pro SKU has the same lower body or port placement. Roller is a wheel. Main Circuit Breaker and Battery Switch are separate source labels. Full embedded switch-photo content beyond the printed crop is not promoted to new interface claims. [![Connection-side terminal labels](https://au.elvorka.com/assets/product-details/tr-pro-terminal-labels.png)](https://au.elvorka.com/assets/product-details/tr-pro-terminal-labels.png) Connection-side terminal labels Battery terminals, switch, Wi-Fi antenna and communication ports on the cabinet side. [![Main breaker and folding handle](https://au.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png)](https://au.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png) Main breaker and folding handle Main circuit breaker and folding handle on the illustrated cabinet side. [![Original connection-side three-quarter view](https://au.elvorka.com/assets/product-details/tr-pro-connection-side.png)](https://au.elvorka.com/assets/product-details/tr-pro-connection-side.png) Original connection-side three-quarter view Connection-side view of the cabinet, battery terminals and folding handle. [![Original narrow side profile](https://au.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png)](https://au.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png) Original narrow side profile Narrow side profile of the illustrated cabinet. [![Original circuit-switch photograph](https://au.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png)](https://au.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png) Original circuit-switch photograph Circuit-control switch with ON and OFF position markings. ### Know your interfaces. #### Power connections Positive battery terminal Positive DC battery terminal identified on the connection side. Negative battery terminal Negative DC battery terminal identified on the connection side. #### Communication RS485 RS485 interface named in the source; pinout and compatible device list are not provided. Wi-Fi antenna Wi-Fi antenna identified by the original arrow. CAN CAN communication interface named in the source; protocol version and pinout are not specified. RS232 RS232 communication interface named in the source; pinout is not specified. COM1 Port named COM1; this page does not explicitly define its role or wiring. COM0 Port named COM0; this page does not explicitly define its role or wiring. #### Controls & indicators Breathing light Front status-light strip identified as a breathing light. Colour meanings and operating logic are not specified. Main circuit breaker Main circuit breaker identified by the original arrow. Trip ratings and wiring are not provided here. Battery switch Battery switch separately named in the connection-side callout; do not merge this label with Main Circuit Breaker without a model-specific manual. #### Structure & mounting Wall-mounted bracket Mechanical wall-mounting bracket; not an electrical interface. Rollers Wheels shown on the representative housing. The label is mechanical and is not a connector or bottom communication port. Folding handle Mechanical folding handle; not an electrical connector. Source: Residential ESS brochure · PDF page 4 · printed pages 7-8 --- https://au.elvorka.com/en/products/tr-pro/ ELVORKA · eric@elvorka.com --- # EU 230 V. ![EU 230 V](https://au.elvorka.com/assets/optimized/ed4fde160f2f91fd-1048-q92.webp) Integrated system # EU 230 V. An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW. INVERTER Included ENCLOSURE IP21 NOMINAL ENERGY 10.24 / 16.076 kWh AC CONFIGURATION 230 V AC / 50 or 60 Hz [Start your project ↗](https://au.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Rated AC (kW) | | --- | --- | --- | | 6.2K-10/16KWH-EU | 10.24 | 6.2 | | 6.2K-10/16KWH-EU | 16.076 | 6.2 | | 12K-16KWH-EU | 16.076 | 12 | 6.2 kW AC configurations: 1 MPPT and max. PV 6.5 kW. 12 kW AC: 2 MPPT and max. PV 2 × 9 kW. Wi-Fi, parallel operation and CT options require confirmation. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | 6.2K-10/16KWH-EU | 552 × 254 × 1210 / L × W × H | 105 | | 6.2K-10/16KWH-EU | 552 × 254 × 1210 / L × W × H | 130 | | 12K-16KWH-EU | 552 × 254 × 1210 / L × W × H | 130 | Communication: USB / RS485 / dry contact Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C ENCLOSURE IP21 01 ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? 02 ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? 03 ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? Specifications - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. Views and numbering come only from the supplied one-page EU brochure. The source does not provide pinouts, cable sizing, wiring procedures or a complete set of every exterior face. Native side-image resolution is modest. A rendered map improves the original vector labels, not the native photographic detail. [![Original numbered interface map](https://au.elvorka.com/assets/product-details/eu-interface-map.png)](https://au.elvorka.com/assets/product-details/eu-interface-map.png) Original numbered interface map Numbered map of the AC, battery, PV and communication connections. [![AC and battery connection side](https://au.elvorka.com/assets/product-details/eu-ac-side-full.png)](https://au.elvorka.com/assets/product-details/eu-ac-side-full.png) AC and battery connection side AC and battery connection side with cooling fans and the battery breaker. [![AC and battery upper detail](https://au.elvorka.com/assets/product-details/eu-ac-side-upper.png)](https://au.elvorka.com/assets/product-details/eu-ac-side-upper.png) AC and battery upper detail Upper AC connection area, cooling fans and BAT terminals. [![PV and communication side](https://au.elvorka.com/assets/product-details/eu-pv-side-full.png)](https://au.elvorka.com/assets/product-details/eu-pv-side-full.png) PV and communication side PV and communication side, including the battery communication ports. [![PV and communication upper detail](https://au.elvorka.com/assets/product-details/eu-pv-side-upper.png)](https://au.elvorka.com/assets/product-details/eu-pv-side-upper.png) PV and communication upper detail Ventilation grille above the PV and communication connection area. ### Know your interfaces. #### Power connections AC input / output The AC connection identified by number 1 in the original map. AC input breaker Breaker labelled for the AC input. BAT+ / BAT- Positive and negative battery terminals, as labelled in the source. PV input Input identified for the PV connection. #### Communication Parallel communication port Communication connection labelled for parallel operation; configuration availability must be confirmed separately. Dry contact control Control interface labelled as dry contact in the brochure. RS485 / BMS communication port The communication connection named RS485/BMS in the original label. Wi-Fi port Port labelled Wi-Fi; the source specification lists Wi-Fi as an option requiring confirmation. USB communication port Communication interface labelled USB. Battery communication ports The source points to the group of three circular openings with label 11. It does not identify these as AC power inputs. #### Controls & indicators Battery breaker Breaker identified for the battery section. Source: EU 230 V product sheet · PDF page 1 --- https://au.elvorka.com/en/products/eu-230v/ ELVORKA · eric@elvorka.com --- # HP Ultra. ![HP Ultra](https://au.elvorka.com/assets/optimized/aad85a50fc62c866-1254-q92.webp) High-voltage battery # HP Ultra. A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter. INVERTER Compatible external inverter required ENCLOSURE IP66 / aluminium alloy NOMINAL ENERGY 8–48 kWh BATTERY VOLTAGE Confirm selected configuration [Start your project ↗](https://au.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Max. DC (kW) | | --- | --- | --- | | HP Ultra-8.0 | 8 | 4 | | HP Ultra-16.0 | 16 | 8 | | HP Ultra-24.0 | 24 | 12 | | HP Ultra-32.0 | 32 | 16 | | HP Ultra-40.0 | 40 | 20 | | HP Ultra-48.0 | 48 | 24 | System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | HP Ultra-8.0 | 950 × 315 × 575 / W × D × H | 75 | | HP Ultra-16.0 | 950 × 315 × 880 / W × D × H | 130 | | HP Ultra-24.0 | 950 × 315 × 1185 / W × D × H | 185 | | HP Ultra-32.0 | 950 × 315 × 1490 / W × D × H | 240 | | HP Ultra-40.0 | 950 × 315 × 1795 / W × D × H | 295 | | HP Ultra-48.0 | 950 × 315 × 2100 / W × D × H | 350 | Communication: CAN / RS485 / Wi-Fi / Bluetooth Temperature: Confirm selected configuration ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. Temperature: Confirm selected configuration ENCLOSURE IP66 / aluminium alloy 01 ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? 02 ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? 03 ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? Specifications - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models. [![DC electrical / heatsink face - original callouts](https://au.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)](https://au.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png) DC electrical / heatsink face - original callouts DC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate. [![Communication and parallel-interface face - original callouts](https://au.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)](https://au.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png) Communication and parallel-interface face - original callouts Communication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND. [![Communication-side detail (partial oblique view)](https://au.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)](https://au.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png) Communication-side detail (partial oblique view) Oblique detail of the stack's communication-side connector area. [![Module top / mating surfaces](https://au.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)](https://au.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png) Module top / mating surfaces Battery module top and mating surfaces. ### Know your interfaces. #### Power connections Positive Pole Positive terminal identified by the original leader line on the electrical face. Negative Pole Negative terminal identified by the original leader line on the electrical face. #### Communication Bluetooth/WIFI Antenna Antenna label on the upper communication-side area. Backup Com The brochure labels this connection 'Backup Com' but does not explain its exact role. INV CAN/RS485 Com The INV-labelled CAN/RS485 communication connection shown in the original diagram. Parallel COM1 First parallel-communication label near the lower part of the illustrated interface face. Parallel COM2 Second parallel-communication label near the lower part of the illustrated interface face. #### Controls & indicators Switch Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified. DC Breaker DC breaker on the electrical / heatsink face. Breathing Light Light strip called out at the upper front portion in the oblique construction view. #### Structure & mounting Heat Dissipation Aluminum Plate Heat-dissipation aluminum plate called out on the slim electrical-side illustration. Wall Mounted Bracket Mounting brackets shown on the vent-side illustration. PDU PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation. Module Repeated battery sections below the top PDU. Base Base at the bottom of the illustrated stack. BMS Debugging Interface BMS debugging interface identified on the communication-side illustration. Pressure Relief Valve Pressure-relief component called out in the communication-side oblique view. GND Ground connection labelled GND at the bottom of the interface-side illustration. Source: Residential ESS brochure · PDF page 5 · printed pages 9-10 --- https://au.elvorka.com/en/products/hp-ultra/ ELVORKA · eric@elvorka.com --- # TA6000. ![TA6000](https://au.elvorka.com/assets/optimized/3767e02b99d59eea-1254-q92.webp) Integrated system # TA6000. Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration. INVERTER Included ENCLOSURE Not specified NOMINAL ENERGY 10.24–20.48 kWh AC CONFIGURATION 120 V US / 230 V EU AC options [Start your project ↗](https://au.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | AC options (kW) | | --- | --- | --- | | TA6000-M2 | 10.24 | 6–10 | | TA6000-M3 | 15.36 | 6–12 | | TA6000-M4 | 20.48 | 6–12 | Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | TA6000-M2 | 590 × 570 × 1880 / W × D × H | 244 | | TA6000-M3 | 590 × 570 × 1880 / W × D × H | 286 | | TA6000-M4 | 590 × 570 × 1880 / W × D × H | 328 | Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional Temperature: Operating −20 to 60 °C ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. Temperature: Operating −20 to 60 °C ENCLOSURE Not specified 01 ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? 02 ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? 03 ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? Specifications - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility. [![Original terminal labels](https://au.elvorka.com/assets/product-details/ta-terminal-map.png)](https://au.elvorka.com/assets/product-details/ta-terminal-map.png) Original terminal labels Connection panel labelled for load, grid, optional generator, PV and communication. [![Terminal panel close-up](https://au.elvorka.com/assets/product-details/ta-terminal-closeup.png)](https://au.elvorka.com/assets/product-details/ta-terminal-closeup.png) Terminal panel close-up Close-up of the cabinet terminal panel. [![Original breaker labels](https://au.elvorka.com/assets/product-details/ta-breaker-map.png)](https://au.elvorka.com/assets/product-details/ta-breaker-map.png) Original breaker labels Battery, PV1, PV2, load and grid breakers in the illustrated compartment. [![Breaker compartment close-up](https://au.elvorka.com/assets/product-details/ta-breaker-closeup.png)](https://au.elvorka.com/assets/product-details/ta-breaker-closeup.png) Breaker compartment close-up Circuit breakers within the cabinet's breaker compartment. [![Upper cabinet and service bay](https://au.elvorka.com/assets/product-details/ta-service-bay.png)](https://au.elvorka.com/assets/product-details/ta-service-bay.png) Upper cabinet and service bay Upper cabinet compartment with the inverter and connection area. [![Cell assembly detail](https://au.elvorka.com/assets/product-details/ta-cell-assembly.png)](https://au.elvorka.com/assets/product-details/ta-cell-assembly.png) Cell assembly detail Battery cell tops in a partial internal illustration. ### Know your interfaces. #### Power connections Load Output Output position identified as Load Output in the brochure. Grid Input Connection position identified as Grid Input. Generator Input (optional) The generator input is explicitly marked optional in the original callout. PV Input PV connection area identified by the original callout. PV1 Input Breaker Breaker identified for PV1 Input. PV2 Input Breaker Breaker identified for PV2 Input. #### Communication Communication Port Connection area labelled Communication Port. No protocol pin assignments are specified in this component view. #### Controls & indicators Battery Breaker Breaker labelled for the battery section. Load Breaker Breaker identified for the load connection. Grid Breaker Breaker identified for the grid connection. Source: Residential ESS brochure · PDF page 8 · printed pages 15-16 --- https://au.elvorka.com/en/products/ta6000/ ELVORKA · eric@elvorka.com --- # TR standard. ![TR standard](https://au.elvorka.com/assets/optimized/54d556eb3b41e40a-1295-q92.webp) Low-voltage battery # TR standard. Five specified capacities in a wall-mounted LFP battery format. Select the capacity, enclosure and a compatible external inverter for the installation. INVERTER Compatible external inverter required ENCLOSURE IP20; IP54 optional NOMINAL ENERGY 5.12–20.07 kWh BATTERY VOLTAGE 51.2 V nominal DC [Start your project ↗](https://au.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Nominal DC (V) | | --- | --- | --- | | TR4000WX | 5.12 | 51.2 | | TR6000WX | 10.24 | 51.2 | | TR8000WX | 14.336 | 51.2 | | TR8500WX | 16.076 | 51.2 | | TR10000WX | 20.07 | 51.2 | Self-heating is optional. Confirm the charge/discharge current, output power and enclosure option for the exact model and inverter. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | TR4000WX | 400 × 750 × 160 / W × H × D | 53.5 | | TR6000WX | 600 × 750 × 160 / W × H × D | 95 | | TR8000WX | 480 × 822 × 245 / W × H × D | 110 | | TR8500WX | 480 × 822 × 245 / W × H × D | 115 | | TR10000WX | 500 × 922 × 265 / W × H × D | 145 | Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth Temperature: Charge 0 to 55 °C ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. Temperature: Charge 0 to 55 °C ENCLOSURE IP20; IP54 optional 01 ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? 02 ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? 03 ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? Specifications - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. Five model names provide family context, but the compact callout housing is not individually assigned to a SKU. The roller annotation expressly names TR8000WX and TR8500WX. Native photo detail is limited; no replacement surface or port detail is synthesized. [![Front controls and side terminals](https://au.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)](https://au.elvorka.com/assets/product-details/tr-standard-controls-annotated.png) Front controls and side terminals Touch screen, status indicators, communication ports and DC terminals on the illustrated cabinet. [![Rear bracket and terminal-side labels](https://au.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)](https://au.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png) Rear bracket and terminal-side labels Rear mounting bracket and side terminal area of the illustrated battery. [![Circuit control switch detail](https://au.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)](https://au.elvorka.com/assets/product-details/tr-standard-switch-closeup.png) Circuit control switch detail Circuit control switch with ON/OFF markings. [![Original rear three-quarter view](https://au.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)](https://au.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png) Original rear three-quarter view Rear three-quarter view showing the mounting bracket and terminal side. [![Original side profile](https://au.elvorka.com/assets/product-details/tr-standard-side-profile.png)](https://au.elvorka.com/assets/product-details/tr-standard-side-profile.png) Original side profile Side profile showing communication ports and the recessed handle. ### Know your interfaces. #### Power connections Negative battery terminal Negative DC battery power terminal as identified by the original arrow. Positive battery terminal Positive DC battery power terminal as identified by the original arrow. #### Communication Wi-Fi / Bluetooth Wi-Fi/Bluetooth feature identified in the callout; no app or pairing workflow is established here. Dry contact Dry-contact interface identified; contact logic, pinout and electrical ratings are not supplied. RS232 / CAN / RS485 Communications interfaces named in the source; protocol compatibility and wiring require separate confirmation. COM0 / COM1 Ports named COM0/COM1. This page does not state their role, pinout or parallel-system limits. #### Controls & indicators Touch screen Touch-screen display identified in the original callout. Running status indicator Running-status indication; source spelling is 'Runing Status'. Indicator logic is not specified. Alarm indicator Alarm indication identified in the source. SOC indicator SOC indicator identified in the source; display thresholds are not specified. Reset control Reset control identified by the source; operating procedure is not given on this page. Battery switch Battery switch identified in the source; no switching rating is given in this callout. #### Structure & mounting Folding handle Mechanical folding handle; not an electrical connector. Wall-mounted bracket Wall-mounting bracket identified in the source; mounting load and fixing details are not supplied here. Rollers Rollers; the original annotation explicitly names TR8000WX and TR8500WX. Not an electrical interface. Source: Residential ESS brochure · PDF page 3 · printed pages 5-6 --- https://au.elvorka.com/en/products/tr-standard/ ELVORKA · eric@elvorka.com --- # HP K. ![HP K](https://au.elvorka.com/assets/optimized/06e5e5950abd6ed8-1405-q92.webp) High-voltage battery # HP K. Four to eight LFP battery modules in five specified stacked configurations. Match the selected voltage and communication settings to a compatible external inverter. INVERTER Compatible external inverter required ENCLOSURE IP20; IP54 optional NOMINAL ENERGY 20.48–40.96 kWh BATTERY VOLTAGE 204.8–409.6 V nominal DC [Start your project ↗](https://au.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Rated DC (kW) | | --- | --- | --- | | HP2000K | 20.48 | 20 | | HP2500K | 25.6 | 25 | | HP3000K | 30.72 | 30 | | HP3500K | 35.84 | 35 | | HP4000K | 40.96 | 40 | Battery-side DC ratings are not inverter AC output ratings. Confirm the inverter DC voltage window for the chosen module count. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | HP2000K | 580 × 390 × 918 / L × W × H | 213 | | HP2500K | 580 × 390 × 1089 / L × W × H | 259.5 | | HP3000K | 580 × 390 × 1260 / L × W × H | 306 | | HP3500K | 580 × 390 × 1431 / L × W × H | 352.5 | | HP4000K | 580 × 390 × 1602 / L × W × H | 399 | Communication: RS485 / CAN; Wi-Fi / Bluetooth optional Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ENCLOSURE IP20; IP54 optional 01 ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? 02 ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? 03 ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? Specifications - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. The original front/color-screen diagram shows four 5.12kWh sections; the family specification table spans four to eight modules. The connection/control face is not explicitly named rear. No separate GND, parallel COM1/COM2, INV CAN/RS485 or BMS debugging label is printed for this family, so none is imported from HP Ultra. The brochure supplies no pinout or installation/activation sequence. [![Connection/control face - original labels](https://au.elvorka.com/assets/product-details/hp-k-interface-callouts.png)](https://au.elvorka.com/assets/product-details/hp-k-interface-callouts.png) Connection/control face - original labels COM1 reserve, COM2 inverter connection, DC24V/AC230V activation and control switches. [![Color-screen face](https://au.elvorka.com/assets/product-details/hp-k-front-screen-face.png)](https://au.elvorka.com/assets/product-details/hp-k-front-screen-face.png) Color-screen face Front view of the color-screen unit and stacked battery modules. [![PDU connector and control detail](https://au.elvorka.com/assets/product-details/hp-k-pdu-interface-detail.png)](https://au.elvorka.com/assets/product-details/hp-k-pdu-interface-detail.png) PDU connector and control detail Top-unit panel with connectors, indicators and switches. [![Color-screen top-unit detail](https://au.elvorka.com/assets/product-details/hp-k-color-screen-detail.png)](https://au.elvorka.com/assets/product-details/hp-k-color-screen-detail.png) Color-screen top-unit detail Color-screen area on the front of the top unit. [![Separated module stack detail](https://au.elvorka.com/assets/product-details/hp-k-separated-modules-detail.png)](https://au.elvorka.com/assets/product-details/hp-k-separated-modules-detail.png) Separated module stack detail Separated battery modules showing their mating surfaces. ### Know your interfaces. #### Power connections Negative Pole Negative terminal as identified by the original leader line. Positive Pole Positive terminal as identified by the original leader line. Battery Activation (DC24V) A separately labelled DC24V battery-activation point in the original connection-face diagram. Battery Activation (AC230V) A separately labelled AC230V battery-activation point in the original connection-face diagram. #### Communication COM1: Reserve COM1 is explicitly labelled Reserve. COM2: Connect To Inverter The source explicitly assigns the inverter connection to COM2. #### Controls & indicators Color Screen Screen identified on the opposite, closed front-top face. Air Switch Switch/breaker labelled Air Switch on the connection/control face. AC Switch A separate control labelled AC Switch. Alarm Lights Alarm indicator group identified by the original leader line. Running Lights Running indicator group identified by the original leader line. Adjustable Status Indicator Feature caption on the separate status-line corner illustration on printed page 11. #### Structure & mounting PDU The top unit identified as PDU above the battery sections; the source does not expand the abbreviation. 5.12kWh Four repeated 5.12kWh sections are called out in the introduction diagram. Chassis Bottom chassis called out below the battery stack. Source: Residential ESS brochure · PDF page 6 · printed pages 11-12 --- https://au.elvorka.com/en/products/hp-k/ ELVORKA · eric@elvorka.com --- # TB rack. ![TB rack](https://au.elvorka.com/assets/optimized/2b8fe35077745c40-1584-q92.webp) Low-voltage battery # TB rack. Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter. INVERTER Compatible external inverter required ENCLOSURE IP20 NOMINAL ENERGY 5.12–16.076 kWh BATTERY VOLTAGE 51.2 V nominal DC [Start your project ↗](https://au.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Rated DC (kW) | | --- | --- | --- | | TB4000X | 5.12 | 5 | | TB6000X | 10.24 | 10 | | TB8000X | 14.336 | 10 | | TB8500X | 16.076 | 10 | Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | TB4000X | 482 × 178 × 420 / W × H × D | 42 | | TB6000X | 482 × 223 × 550 / W × H × D | 78 | | TB8000X | 482 × 223 × 710 / W × H × D | 109.5 | | TB8500X | 482 × 223 × 710 / W × H × D | 112 | Communication: RS485 / CAN / RS232 Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ENCLOSURE IP20 01 ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? 02 ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? 03 ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? Specifications - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos. [![Original front terminal and control strip](https://au.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)](https://au.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png) Original front terminal and control strip Front terminal and control strip, with the negative terminal left and positive terminal right. [![Negative power terminal, front left](https://au.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)](https://au.elvorka.com/assets/product-details/tb-rack-negative-terminal.png) Negative power terminal, front left Negative terminal and minus mark at the front left. [![Positive power terminal, front right](https://au.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)](https://au.elvorka.com/assets/product-details/tb-rack-positive-terminal.png) Positive power terminal, front right Positive terminal and plus mark at the front right. [![Original communication and control area](https://au.elvorka.com/assets/product-details/tb-rack-communication-controls.png)](https://au.elvorka.com/assets/product-details/tb-rack-communication-controls.png) Original communication and control area Communication connectors, indicators and power switch on the front control strip. [![Original cell and BMS construction detail](https://au.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)](https://au.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png) Original cell and BMS construction detail Partial internal illustration showing battery cells and the BMS board. ### Know your interfaces. #### Power connections Positive power terminal Power port on the viewer's right in the illustrated front panel, with the original plus mark. Negative power terminal Power port on the viewer's left in the illustrated front panel, with the original minus mark. #### Communication Dry Connect (source label) Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given. COM0 / COM1 parallel ports Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied. CAN / RS485 Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol. RS232 Communication port named RS232; exact pinout and adapter requirements are not provided. #### Controls & indicators Power switch Power on/off switch as described in the original caption. Operating sequence is not supplied. SOC / ALM / RUN indicators Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified. Address identification control Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified. #### Structure & mounting Laser welding The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port. Steel holder Internal steel holder identified as fixing the cells; not an external connector. Plastic steel belt (source wording) Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated. Built-in smart BMS Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions. Portable handle Steel handle as described in the source. It is not an electrical port. Source: Residential ESS brochure · PDF page 7 · printed pages 13-14 --- https://au.elvorka.com/en/products/tb-rack/ ELVORKA · eric@elvorka.com --- # A clearer view of home storage. Journal / Australia # A clearer view of home storage. Practical reading for choosing battery capacity, checking equipment-room conditions and preparing a useful installation brief. Journal ## [How much battery storage does your home need?](https://au.elvorka.com/en/blog/battery-capacity/) Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. [Read article](https://au.elvorka.com/en/blog/battery-capacity/) Journal ## [Choose the battery location before installation.](https://au.elvorka.com/en/blog/installation-environment/) Room temperature, moisture, access and system architecture matter more than a national climate average. [Read article](https://au.elvorka.com/en/blog/installation-environment/) ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://au.elvorka.com/en/contact/) --- https://au.elvorka.com/en/blog/ ELVORKA · eric@elvorka.com --- # Inside the ELVORKA collection. News / Australia # Inside the ELVORKA collection. Published product resources and website updates, with a clear distinction between documented specifications and project-specific requirements. News ## [The international ELVORKA product collection is available online.](https://au.elvorka.com/en/news/product-collection/) Seven product families, 29 listed configurations and language-specific product guides, now linked from the market editions. [Read article](https://au.elvorka.com/en/news/product-collection/) News ## [Original product views and interface notes are now easier to explore.](https://au.elvorka.com/en/news/technical-library/) 35 source figures and 97 labelled features connect the product pages to a more detailed technical library. [Read article](https://au.elvorka.com/en/news/technical-library/) ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://au.elvorka.com/en/contact/) --- https://au.elvorka.com/en/news/ ELVORKA · eric@elvorka.com --- # How much battery storage does your home need? Journal / Australia # How much battery storage does your home need? Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. ELVORKA Product Desk Published 2026-11-05 Australia ![ELVORKA · Australia · About the images](https://au.elvorka.com/assets/optimized/f5e5c77bf1c7c797-1536-q92.webp) Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. A battery is easier to size when the question is specific: which appliances should keep running, and for how long? A list of selected circuits is more useful than a promise of whole-home backup. Use the local examples below as a starting worksheet, then replace every assumption with appliance or installer data. ## kWh and kW answer different questions Energy in kWh describes the amount stored. Power in kW describes how quickly energy is delivered. A larger battery does not automatically provide a higher AC output. Battery-side DC ratings, inverter AC output, starting demand and the backup-circuit arrangement must all support the intended loads. ## A local load worksheet ### Work from home · 200 W - Laptop allowance: 80 W - Monitor: 40 W - Router: 20 W - Task lighting: 30 W - Small accessories: 30 W ### Selected evening essentials · 450 W - Refrigerator running allowance: 150 W - Freezer running allowance: 100 W - Television: 100 W - Selected LED lighting: 80 W - Router: 20 W ### Essentials with selected cooling · 900 W - Small air-conditioner running allowance: 700 W - Refrigerator running allowance: 150 W - Router: 20 W - Selected lighting: 30 W Illustrative planning allowances, not measured household averages or guaranteed runtime. Replace with actual simultaneous loads and check compressor starting demand, battery DC capability, inverter AC output and backup-capable circuits. ## An indicative runtime, with assumptions visible For comparison only: runtime in hours = nominal battery energy × assumed usable fraction × assumed conversion efficiency ÷ average load in kW. The example uses 90% usable energy and 90% conversion efficiency as planning assumptions, not product guarantees. Actual runtime also depends on reserve settings, temperature, ageing, standby consumption, duty cycles and the selected inverter. ### Illustrative TR6000WX-Pro example | Assumed load (W) | Indicative runtime (h) | | --- | --- | | 200 | 41.5 | | 450 | 18.4 | | 900 | 9.2 | 10.24 kWh nominal energy; assumptions 0.90 × 0.90. This is a calculation, not a tested local household result. ## Choose the architecture before the capacity EU 230 V and TA6000 are integrated battery-and-inverter families. A second standalone inverter is not part of their basic product architecture. TR Pro, TR standard, HP Ultra, HP K and TB are batteries that need a compatible external inverter. Match voltage range, current limits, communication protocol and firmware; nominal voltage alone does not establish compatibility. [Backup explorer](https://au.elvorka.com/en/#planner) Use the backup explorer for a first comparison, then send the selected loads, required duration and existing inverter details with your enquiry. Electrical design and final compatibility need to be confirmed for the actual project. ## Questions for your installer ### Can I add one of these batteries to my existing inverter? Only after checking the exact inverter model and firmware against the battery voltage window, current limits and communication protocol. A battery-only product needs a compatible external inverter; an existing system or a matching nominal voltage alone does not establish compatibility. ### Will this battery work with my VPP or qualify for an incentive? Confirm the selected equipment and firmware with the specific provider or programme before ordering. VPP control, operating requirements and participation terms are separate checks. This catalogue does not promise VPP compatibility, eligibility, savings or local approval. ### Can one placement suit both summer heat and winter cold? Assess the full expected temperature range, humidity and exposure at the battery position. Several families list charging from 0 °C, and heating is optional only where specified. Confirm the selected model's limits, protection, ventilation and any derating rather than relying on a national climate average. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://au.elvorka.com/en/contact/) ## Continue exploring Journal ## [Choose the battery location before installation.](https://au.elvorka.com/en/blog/installation-environment/) Room temperature, moisture, access and system architecture matter more than a national climate average. [Read article](https://au.elvorka.com/en/blog/installation-environment/) News ## [Original product views and interface notes are now easier to explore.](https://au.elvorka.com/en/news/technical-library/) 35 source figures and 97 labelled features connect the product pages to a more detailed technical library. [Read article](https://au.elvorka.com/en/news/technical-library/) --- https://au.elvorka.com/en/blog/battery-capacity/ ELVORKA · eric@elvorka.com --- # Choose the battery location before installation. Journal / Australia # Choose the battery location before installation. Room temperature, moisture, access and system architecture matter more than a national climate average. ELVORKA Product Desk Published 2026-11-05 Australia ![ELVORKA · Australia · About the images](https://au.elvorka.com/assets/optimized/abd8659c1668624f-1536-q92.webp) Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. A dry utility room, a seasonally hot garage and a coastal service area place different demands on equipment. Assess conditions where the battery will stand, including the coldest and hottest periods. The following local profiles help frame the questions; they do not certify a particular installation. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. ## Different climates. A specific place for your battery. ### Summer heat · garage or dedicated utility room Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable. Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. Questions for your installer - Does the room trap afternoon or roof heat? - What temperature and output derating apply to this exact configuration? - Can cooling and service space remain clear after installation? ### Tropical north · humidity and actual exposure The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment. Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air. Questions for your installer - Is the room dry through the wet season? - Can water, condensation or coastal salt reach the equipment? - Does the exact model's placement guidance cover the proposed environment? ### Cooler winter location · southern or elevated home Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home. If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation. Questions for your installer - Can the battery position fall below 0 °C while charging? - Is heating included and confirmed for this exact model? - Does the equipment room stay dry during cold-to-warm changes? ### Planning notes - Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings. - Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature. - Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray. ## Keep charging and discharging limits separate The TR Pro literature lists charging at 0–55 °C and discharging at −20–60 °C. The colder discharge boundary is not permission to charge below zero. Self-heating is optional and must be confirmed for the exact configuration. HP Ultra temperature limits require configuration confirmation; do not transfer another family's limits to it. ## Read the views, then request the exact manual The technical library retains the original product views and numbered interface labels. A visible connector is not enough to infer a pinout, polarity or power rating. Confirm the selected model's wiring diagram, protection, cable requirements, clearances, torque values and communication settings from its installation documentation. The scene illustrations are visual references, not wiring instructions. [Original views & interfaces](https://au.elvorka.com/en/#technical-library) Record the proposed room, expected temperatures, moisture exposure and maintenance access. For an integrated system, confirm the required AC configuration. For a battery-only system, include the existing inverter model and DC voltage range in the brief. ## Questions for your installer ### Can I add one of these batteries to my existing inverter? Only after checking the exact inverter model and firmware against the battery voltage window, current limits and communication protocol. A battery-only product needs a compatible external inverter; an existing system or a matching nominal voltage alone does not establish compatibility. ### Will this battery work with my VPP or qualify for an incentive? Confirm the selected equipment and firmware with the specific provider or programme before ordering. VPP control, operating requirements and participation terms are separate checks. This catalogue does not promise VPP compatibility, eligibility, savings or local approval. ### Can one placement suit both summer heat and winter cold? Assess the full expected temperature range, humidity and exposure at the battery position. Several families list charging from 0 °C, and heating is optional only where specified. Confirm the selected model's limits, protection, ventilation and any derating rather than relying on a national climate average. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://au.elvorka.com/en/contact/) ## Continue exploring Journal ## [How much battery storage does your home need?](https://au.elvorka.com/en/blog/battery-capacity/) Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. [Read article](https://au.elvorka.com/en/blog/battery-capacity/) News ## [The international ELVORKA product collection is available online.](https://au.elvorka.com/en/news/product-collection/) Seven product families, 29 listed configurations and language-specific product guides, now linked from the market editions. [Read article](https://au.elvorka.com/en/news/product-collection/) --- https://au.elvorka.com/en/blog/installation-environment/ ELVORKA · eric@elvorka.com --- # The international ELVORKA product collection is available online. News / Australia # The international ELVORKA product collection is available online. Seven product families, 29 listed configurations and language-specific product guides, now linked from the market editions. ELVORKA Product Desk Published 2026-11-05 Australia ![ELVORKA · Australia · About the images](https://au.elvorka.com/assets/optimized/abd8659c1668624f-1536-q92.webp) Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. The current online collection brings the supplied product literature into a common ELVORKA format. It covers integrated storage systems and battery-only families. Solar panels and standalone inverters are not products offered in this collection. Each market edition combines model specifications, local installation-environment questions, illustrative appliance loads and a downloadable product guide. The language selector keeps equivalent pages connected. The United States English edition is the main website; dedicated country editions remain directly accessible. ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. ## Products | Products | Model | Nominal energy (kWh) | | --- | --- | --- | | TR Pro | TR6000WX-Pro | 10.24 | | | TR8500WX-Pro | 16.076 | | | TR8500WX-ProU | 16.076 | | EU 230 V | 6.2K-10/16KWH-EU | 10.24 | | | 6.2K-10/16KWH-EU | 16.076 | | | 12K-16KWH-EU | 16.076 | | HP Ultra | HP Ultra-8.0 | 8 | | | HP Ultra-16.0 | 16 | | | HP Ultra-24.0 | 24 | | | HP Ultra-32.0 | 32 | | | HP Ultra-40.0 | 40 | | | HP Ultra-48.0 | 48 | | TA6000 | TA6000-M2 | 10.24 | | | TA6000-M3 | 15.36 | | | TA6000-M4 | 20.48 | | TR standard | TR4000WX | 5.12 | | | TR6000WX | 10.24 | | | TR8000WX | 14.336 | | | TR8500WX | 16.076 | | | TR10000WX | 20.07 | | HP K | HP2000K | 20.48 | | | HP2500K | 25.6 | | | HP3000K | 30.72 | | | HP3500K | 35.84 | | | HP4000K | 40.96 | | TB rack | TB4000X | 5.12 | | | TB6000X | 10.24 | | | TB8000X | 14.336 | | | TB8500X | 16.076 | ## What the collection establishes The model tables reproduce supplied literature. They are not a statement of local stock, certification, grid approval, installer coverage or a standard warranty in every market. Request the exact configuration, documents and commercial terms for your project. Installation scenes are branded illustrations, not evidence of completed customer installations. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://au.elvorka.com/en/contact/) ## Continue exploring Journal ## [How much battery storage does your home need?](https://au.elvorka.com/en/blog/battery-capacity/) Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. [Read article](https://au.elvorka.com/en/blog/battery-capacity/) --- https://au.elvorka.com/en/news/product-collection/ ELVORKA · eric@elvorka.com --- # Original product views and interface notes are now easier to explore. News / Australia # Original product views and interface notes are now easier to explore. 35 source figures and 97 labelled features connect the product pages to a more detailed technical library. ELVORKA Product Desk Published 2026-11-05 Australia ![ELVORKA · Australia · About the images](https://au.elvorka.com/assets/optimized/f5e5c77bf1c7c797-1536-q92.webp) Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. The product library includes the source material's front, side, rear and interface illustrations where supplied. The set contains 35 figures and 97 labelled features across the collection; the number and kind of views vary by family. Use the numbered view selector to move between available illustrations. Interface notes identify labels found in the supplied material and preserve their source context. The downloadable views-and-interfaces guide provides a consolidated reference for discussion with an installer. [Original views & interfaces](https://au.elvorka.com/en/#technical-library) ## Summer heat · garage or dedicated utility room Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration. [TR Pro ↗](https://au.elvorka.com/en/products/tr-pro/#technical-views)[EU 230 V ↗](https://au.elvorka.com/en/products/eu-230v/#technical-views)[HP Ultra ↗](https://au.elvorka.com/en/products/hp-ultra/#technical-views)[TA6000 ↗](https://au.elvorka.com/en/products/ta6000/#technical-views)[TR standard ↗](https://au.elvorka.com/en/products/tr-standard/#technical-views)[HP K ↗](https://au.elvorka.com/en/products/hp-k/#technical-views)[TB rack ↗](https://au.elvorka.com/en/products/tb-rack/#technical-views) ## What the collection establishes These figures improve product identification. They do not establish an undocumented pinout, prove an installation complies with local rules, or replace the selected model's current installation manual. Ask for confirmation whenever a connector function or configuration is not explicitly documented. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://au.elvorka.com/en/contact/) ## Continue exploring Journal ## [How much battery storage does your home need?](https://au.elvorka.com/en/blog/battery-capacity/) Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. [Read article](https://au.elvorka.com/en/blog/battery-capacity/) News ## [The international ELVORKA product collection is available online.](https://au.elvorka.com/en/news/product-collection/) Seven product families, 29 listed configurations and language-specific product guides, now linked from the market editions. [Read article](https://au.elvorka.com/en/news/product-collection/) --- https://au.elvorka.com/en/news/technical-library/ ELVORKA · eric@elvorka.com --- # Home storage. Clearly specified. ELVORKA / Australia # Home storage. Clearly specified. ELVORKA presents integrated storage systems and battery-only products for residential energy projects. The collection is organised around the equipment, the room it will occupy and the loads it needs to support. ELVORKA presents integrated storage systems and battery-only products for residential energy projects. The collection is organised around the equipment, the room it will occupy and the loads it needs to support. Compare the documented models, inspect the original technical views and prepare a project brief in the language edition most useful to you. Market pages address local installation conditions without treating an entire country as one climate or one electrical configuration. ## Choose the architecture before the capacity EU 230 V and TA6000 are integrated battery-and-inverter families. A second standalone inverter is not part of their basic product architecture. TR Pro, TR standard, HP Ultra, HP K and TB are batteries that need a compatible external inverter. Match voltage range, current limits, communication protocol and firmware; nominal voltage alone does not establish compatibility. ## Different climates. A specific place for your battery. Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position. ## How enquiries work The enquiry form sends the details you choose to provide to the protected ELVORKA project desk, where they are saved for review and follow-up and made available to the authorised mobile work inbox. The submission includes its market, language, page and reported referral/UTM source; IP location is approximate. First/latest visit source notes are held in this browser session and sent only with an enquiry. A colour preference may be stored locally. You can also save a local copy or contact eric@elvorka.com by email. Pages are delivered through Cloudflare. ## What the collection establishes The model tables reproduce supplied literature. They are not a statement of local stock, certification, grid approval, installer coverage or a standard warranty in every market. Request the exact configuration, documents and commercial terms for your project. Installation scenes are branded illustrations, not evidence of completed customer installations. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://au.elvorka.com/en/contact/) --- https://au.elvorka.com/en/about/ ELVORKA · eric@elvorka.com --- # Clear sources. Visible limits. ELVORKA / Australia # Clear sources. Visible limits. Model facts are taken from the supplied residential storage and EU integrated-system literature. Regional environment notes use the public sources linked below. Planning assumptions and visual illustrations are identified separately. Model facts are taken from the supplied residential storage and EU integrated-system literature. Regional environment notes use the public sources linked below. Planning assumptions and visual illustrations are identified separately. ## Product evidence The product tables, original technical figures and labelled interface notes are the primary reference set for this website. Specifications can vary by exact model and configuration. The current installation manual, compatibility confirmation and project documents remain necessary before purchase or installation. [Original views & interfaces](https://au.elvorka.com/en/#technical-library) ## About the images Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. ## Regional context sources - [Australian Bureau of Meteorology](https://www.bom.gov.au/resources/learn-and-explore/climate-knowledge-centre/australian-climate-zones) - [Australian Competition and Consumer Commission](https://www.accc.gov.au/media-release/growing-home-battery-uptake-delivering-lower-electricity-bills-but-consumer-protections-needed) ## Readable by people and software The same public product information is available as HTML, Markdown and a structured catalogue. These formats support accurate retrieval and citation; they do not add claims, certifications or hidden content. Prefer the linked canonical page and its model-specific qualifications when quoting a specification. - [llms.txt](https://au.elvorka.com/llms.txt) - [llms-full.txt](https://au.elvorka.com/llms-full.txt) - [JSON · Products](https://au.elvorka.com/data/product-catalogue.json) For a specification clarification or correction, contact eric@elvorka.com and identify the model, page and source in question. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://au.elvorka.com/en/contact/) --- https://au.elvorka.com/en/sources/ ELVORKA · eric@elvorka.com --- # Let’s plan your storage project. ELVORKA / Australia # Let’s plan your storage project. Tell us where the system will be installed, the loads you want to support and the product you are considering. Your enquiry goes to the ELVORKA project desk. Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [eric@elvorka.com](mailto:eric@elvorka.com) [Explore the full collection](https://au.elvorka.com/en/#products) [Download product guide](https://au.elvorka.com/downloads/ELVORKA_au_en_Product_Guide.pdf) Your name (optional) Project city * Your email Phone / WhatsApp (optional, include country code) Company (optional) I am planning for Existing inverter Product interest What matters to you? State / region and seasonal conditions Lowest / highest observed temperature; damp or water exposure AC supply and required phase arrangement Your submitted details are saved for the ELVORKA team to review and follow up. Please avoid including passwords, identity documents or unrelated sensitive information. I agree that ELVORKA may use these details to respond to this project enquiry. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Email your project ↗](mailto:eric@elvorka.com) --- https://au.elvorka.com/en/contact/ ELVORKA · eric@elvorka.com