TB rack

Low-voltage battery

TB rack.

Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP20
NOMINAL ENERGY
5.12–16.076 kWh
BATTERY VOLTAGE
51.2 V nominal DC
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated DC (kW)
TB4000X5.125
TB6000X10.2410
TB8000X14.33610
TB8500X16.07610

Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC.

ModelDimensions (mm)Approx. kg
TB4000X482 × 178 × 420 / W × H × D42
TB6000X482 × 223 × 550 / W × H × D78
TB8000X482 × 223 × 710 / W × H × D109.5
TB8500X482 × 223 × 710 / W × H × D112

Communication: RS485 / CAN / RS232
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

Different climates. A specific place for your battery.

Australia spans tropical, subtropical and temperate climates. A warm northern equipment room, a summer-heated garage and a cooler southern or elevated location need different checks at the actual battery position.

Temperature:
Charge 0 to 55 °C; discharge −20 to 60 °C
ENCLOSURE
IP20
01

Summer heat · garage or dedicated utility room

Building materials, roof heat and afternoon sun can change the conditions inside a garage even when the outdoor forecast appears acceptable.

Record the hottest expected temperature at the unit and retain the selected manual's cooling and service space. TR Pro lists charging 0 to 55 °C; that upper boundary is not a full-power guarantee. Confirm HP Ultra temperature limits and any output derating for the selected configuration.

Does the room trap afternoon or roof heat?
  • What temperature and output derating apply to this exact configuration?
  • Can cooling and service space remain clear after installation?
02

Tropical north · humidity and actual exposure

The Bureau of Meteorology describes the tropical north, including Cairns and Darwin, as generally warm and humid, with wet and dry seasons. The indoor location still needs its own exposure assessment.

Choose a dry, protected location assessed for condensation, water entry and coastal exposure. EU all-in-one is IP21; TR Pro and HP Ultra list IP66. An IP rating alone does not establish suitability for condensation, floodwater or salt-laden air.

Is the room dry through the wet season?
  • Can water, condensation or coastal salt reach the equipment?
  • Does the exact model's placement guidance cover the proposed environment?
03

Cooler winter location · southern or elevated home

Temperate locations such as Melbourne and Hobart have distinct seasons. Check an unheated garage or outbuilding independently from the temperature in the occupied home.

If the battery position can fall below 0 °C, confirm the exact charging protection and any selected heating option. TR Pro lists charging 0 to 55 °C and discharging −20 to 60 °C; its optional self-heating must be confirmed. HP Ultra limits need configuration-specific confirmation.

Can the battery position fall below 0 °C while charging?
  • Is heating included and confirmed for this exact model?
  • Does the equipment room stay dry during cold-to-warm changes?
Specifications
  • Choose the architecture first: EU and TA6000 include an inverter. Battery-only TR, HP and TB families require a compatible external inverter with confirmed voltage, current and communication settings.
  • Check charging and discharging limits separately. Optional heating and a general operating-temperature field do not establish universal subzero charging; a maximum temperature does not promise full output at that temperature.
  • Use the exact enclosure rating and placement instructions. IP21, IP20, optional IP54 and IP66 are different source ratings; none alone establishes resistance to condensation, flooding or coastal salt spray.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos.

Original front terminal and control strip
Original front terminal and control stripFront terminal and control strip, with the negative terminal left and positive terminal right.
Negative power terminal, front left
Negative power terminal, front leftNegative terminal and minus mark at the front left.
Positive power terminal, front right
Positive power terminal, front rightPositive terminal and plus mark at the front right.
Original communication and control area
Original communication and control areaCommunication connectors, indicators and power switch on the front control strip.
Original cell and BMS construction detail
Original cell and BMS construction detailPartial internal illustration showing battery cells and the BMS board.

Know your interfaces.

Power connections

Positive power terminal
Power port on the viewer's right in the illustrated front panel, with the original plus mark.
Negative power terminal
Power port on the viewer's left in the illustrated front panel, with the original minus mark.

Communication

Dry Connect (source label)
Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given.
COM0 / COM1 parallel ports
Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied.
CAN / RS485
Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol.
RS232
Communication port named RS232; exact pinout and adapter requirements are not provided.

Controls & indicators

Power switch
Power on/off switch as described in the original caption. Operating sequence is not supplied.
SOC / ALM / RUN indicators
Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified.
Address identification control
Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified.

Structure & mounting

Laser welding
The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port.
Steel holder
Internal steel holder identified as fixing the cells; not an external connector.
Plastic steel belt (source wording)
Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated.
Built-in smart BMS
Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions.